What was found
CORROSION AROUND ATTACH FWD AND UNDER EDGES OF LAV SINK CABINET FLOOR PAN, BS 304 TO BS 315, RBL 13 TO RBL 41, WL 208. REMOVED CORRODED FLOOR PAN AND FABRICATED NEW PAN REF SRM 51-30-2 PG 3, AND SRM 53-20-1 PG 5 AND 12. TREATED AND PRIMED AND APPLIED TOP COAT TO PAN REF SRM 51-10-2 PG 1. INSTALLED NEW FLOOR PAN, BS 304, RBL 13- RBL 41 REF SRM 51-30-02 PG 2. THIS IS CLASSIFIED AS A MINOR REPAIR.