What was found
MAIN CABIN FLOOR STRUCTURE, LEFT SIDE STA 560 TO 580, LBL 24 SEAT TRACK, INBOARD FLANGE CORRODED ON UPPER SURFACE, FOUND CORROSION TO BE OUT OF LIMITS. NO CORROSION ALLOWED, IAW P-F SRM 53-10-1, FIG 3A PG 3. REPAIRED SEAT RAIL DAMAGE SECTION, STA 560 TO 670, LBL 24, IAW SRM 53-10-5 FIG 1 53-10-2. TREATED AND PRIMED IAW SRM 51-10-2, THIS IS CLASSIFIED AS A MAJOR REPAIR.