What was found
R2 DOOR, CREASE BEAM BETWEEN STA 680 TO 740, RBL 60, S17, HAS SEVERAL AREAS OF CORROSION. REMOVED CORROSION IAW SRM 51-10-02. ORIGINAL MATERIAL .100", AFTER REWORK BLENDED AREA IS L= 48", W= 1.5", D= .085", OUT OF LIMITS IAW SRM 53-30-13, FIG 101. REMOVED AND REPLACED CREASE BEAM IAW SRM 51-10-02 AND 51-40-02.