What was found
CORROSION ON FLOORBEAM AT STA 377.7, LBL3, LBL6, LBL10 AND LBL12. FOUND EXCEED LIMITS IN SRM 53-00-51. REPAIR CARRIED OUT IAW SRM 53-00-51 FIG 201 REPAIR 1 REV. 93. REPAIR IS CLASSIFIED AS MAJOR PER GMM 6-2-100 CRITERIA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM AT STA 377.7, LBL3, LBL6, LBL10 AND LBL12. FOUND EXCEED LIMITS IN SRM 53-00-51. REPAIR CARRIED OUT IAW SRM 53-00-51 FIG 201 REPAIR 1 REV. 93. REPAIR IS CLASSIFIED AS MAJOR PER GMM 6-2-100 CRITERIA.