What was found
PREVIOUS FRAME REPAIR LOCATED IN AFT CARGO ON FRAME 54.2 UNDER FLOOR BETWEEN STRINGERS 54 LT AND 57 HAS 1 REPAIR ANGLE ON THE LOWER AFT SIDE MEASURING 11.7" BY 3" WITH A LOWER FLANGE CUT OUT OF 2.6" BY 1" REPAIR NOT IAW SRM REQUIREMENTS. REMOVED PREVIOUS REPAIR AND INSTALLED CORRECT FRAME REPAIR IAW FED-EX EA 6-5310-117993, DATED 31 DEC 07. THIS IS AN AIRBUS REPAIR WITH NO ASSIGNED PART NUMBER AND IS A RESULT OF AGING AIRCRAFT INSPECTION.