Service difficulty report · Clamp · Doug MD11F

Difficulty date
January 26, 2008
Submitted
January 28, 2008
Operation
Air carrier
Aircraft
N623FE
Make and model
Doug MD11F
Aircraft serial
48794
Aircraft time
28,007 hours, 6,479 cycles
Part
Clamp
Condition
Loose
Location
Anti-Ice Duct
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
E, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 2 ENG ANTI ICE DUCT LIGHT, SHUT DOWN NR 2 ENG AS DIRECTED BY CHECKLIST. REMOVED AND REPLACED ENG 2 ANTI-ICE VLV LATCHING (R2-5527) IAW MD-11 SMP. REMOVED AND REPLACED NR 2 ENG COWL ANTI-ICE MANIFOLD FAILURE SENSING ALL 3 LOOPS (D1-89, D1-90, AND D1-91) IAW MD-11 MM 30-22-11-4. HOOKED UP EQUIPMENT FOR THE NR 2 ENG NOSE COWL ANTI-ICE DUCT LEAK CHECK IAW MD-11MM 30-22-09-5. LEAK CHECK C/W SMALL LEAK FOUND AT COUPLING ON DUCT GOING FROM ENGINE THROUGH FIREWALL. RETORQUED CLAMP LEAK CHECKS GOOD. REMOVED EQUIPMENT, REINSTALLED DUCTING CLOSED PANELS. REACTIVATED ANTI ICE VALVE, RAN ENGINE. OPS CHECKS GOOD.

More about the Doug MD-11F