What was found
NR 2 PYLON PANEL 444BL IS GOUGED IN 2 PLACES AND HAS SURFACE CORROSION. REMOVED CORROSION IAW SRM 54-50-71. ORIGINAL MATERIAL THICKNESS .063. L=1.0", W=.50", D=.011". FOUND TO BE OUT OF SRM 54-50-71, FIG 101 LIMITS, 10 PERCENT MATERIAL LOSS. FABRICATED NEW CHANNEL ON MAE TRAVELER NR T7/715551, FROM 7075-0, 0.063C, HEAT TREATED TO T6. REMOVED AND REPLACED CHANNEL IAW SRM 51-40-01. PAINTED CHANNEL IAW AMM 51-21-00-7.