As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO PIT, FRAME EXTENSION AT BS 600 IS CRACKED IN UPPER RADIUS, ABOVE STR 22L ON FWD SIDE OF FRAME. MARKED END OF CRACK WITH BLACK DOT CIRCLE. GENERATED FROM W/C 53F0020. FABRICATED FRAME EXTENSION REF DWG 53FX1350. HEAT TREATED TO T-6 CONDITION ON 8130 NR 2008-02-083, TREATED AND PRIMED. INSTALLED FRAME EXTENSION. REF SRM 51-30-2/51-10-2. THIS IS CLASSIFIED AS A MINOR REPAIR.