What was found
AFT ENTRY DOOR THRESHOLD HAS AREAS OF DAMAGE (BOTH BULLNOSE PIECES CRACKED) PARTS OF THRESHOLD SENT TO BE FABRICATED AND HEAT TREATED IN SHOP, 8130-3 TRACKING NR 2008-02-125 AND 126. HEAT TREATED TO T4 CONDITION. THRESHOLD RECEIVED FROM SHOP FABRICATED AND IN T4 CONDITION, N00731. LOCATED AND DRILLED FASTENER HOLES AND TREATED AND PRIMED THRESHOLD (1EA FX65-23946-4/FX69-24780-2) REF BOEING DWG 65-23946 AND/SRM 51-10-1, PG 12/SRM 51-10-2. THIS IS CLASSIFIED AS A MINOR REPAIR.