What was found
FWD PIT FLOORBOARD SUPPORT STRG AT (STA 645) RBL 12 IS CORRODED (MARKED ) REMOVED DAMAGED AT STA 645 AND FABED A REPAIR. APPLIED ALODINE, PRIMER AND PAINT. REINSTALLED FLOOR SUPPORT AND INSTALLED SPLICE AT STA 670. APPLIED ALODINE, PRIME AND PAINT, REF SRM 53-10-1 FIG 1. CLASSIFIED AS A MINOR REPAIR.