What was found
CORROSION ON FLOORBEAM AT STA 1280, RBL6, RBL10, RBL14. CORROSION FOUND EXCEED LIMITS IN SRM 53-00-51 FIG 101. REPAIR CARRIED OUT IAW SRM 53-00-51, REPAIR 3, FIG. 201. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM AT STA 1280, RBL6, RBL10, RBL14. CORROSION FOUND EXCEED LIMITS IN SRM 53-00-51 FIG 101. REPAIR CARRIED OUT IAW SRM 53-00-51, REPAIR 3, FIG. 201. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.