What was found
FLOOR SUPPORT BY THE L2 DOOR, STA 700-720, LBL 60, WL208 HAS CORROSION. REMOVED CORROSION FROM FLOOR SUPPORT, L=12.0, W=1.7, D=0.015, ORIGINAL MATERIAL THICKNESS = 0.063. FOUND TO BE OUT OF SRM 53-00-51, FIG 101, DETAIL II AND III LIMITS. REMOVED AND REPLACED FLOOR SUPPORT (U CHANNEL) IAW SRM 51-40-02. REPLACEMENT PART FABRICATED ON MAE TRAVELER T7/713364 FROM 7075-0, 0.056B, HEAT TREATED TO T6 IAW SRM 51-10-02.