What was found
LEFT WING LEADING EDGE APPROXIMATELY STATION XOS = 900 AT HINGE PANEL NR 526FB, INBOARD MOST LATCH MATING SURFACE FLANGE FOUND CORRODED. CORROSION REMOVED AS PER SRM 51-21-01, VOL.II, FOUND OUT OF LIMIT AS PER SRM 57-20- 00, FIG.17, VOL I. ORIGINAL THICKNESS 0.200", MATERIAL REMOVED 0.125" AND REMAINING THICKNESS 0.075". REPAIRED AS PER EA 1-5710-112584, PART 1. REPAIR CLASSIFIED AS CLASSIFIED AS MAJOR REPAIR AS PER GMM 6-2-100.