What was found
FLOOR SUPPORT BY L2 DOOR, BETWEEN STATION 680 TO 700, LBL 60, WL 208 HAS CORROSION. REMOVED CORROSION, FOUND TO BE OUT OF SRM 53-00-51, FIGURE 101, DETAIL III LIMITS, L=1.5 INCH, W= 1 INCH, D= 100 PERCENT. FABRICATED NEW SUPPORT ON MAE TRAVELER NR T7/713362, FROM 7075-0 .050C, HEAT TREATED TO T6. REMOVED AND REPLACED SUPPORT (PN: 143N5136-1) IAW SRM 51-40-02 AND 51-40-05. THIS IS A CATEGORY "A" MAJOR REPAIR WITH NO FOLLOW UP ACTION REQUIRED.