What was found
CORROSION IS ON THE BOTTOM OF THE FLOORBEAM AT FRAME 47; LBL 103CM IN FWD PIT. FOUND TO BE OUT OF LIMITS IAW SRM 52-30-00. REMOVED EDGE MEMBER IAW SRM 51-40-21. REMOVED SEAL RETAINER IAW SRM 51-40-21. RECEIVED NEW EDGE MEMBER IAW SRM 52-31-00. FABBED DOUBLER AND FILLER IAW SRM 52-30-00. INSTALLED DOUBLER & FILLER IAW SRM 51-40-21. INSTALLED EDGE MEMBER & SEAL RETAINER IAW SRM 51-40-21.