What was found
AFT CARGO PIT; FWD BULKHEAD AT FRAME 54; THE CEILING ATTACH ANGLE IS CORRODED FROM 131 TO 139 CM (51.5" TO 54.5 "). REMOVED CORROSION IAW SRM 51-74-10. ORIGINAL MATERIAL THICKNESS .098. REMAINING LATERIAL .050. MATERIAL REMOVED .048. OUT OF LIMITS IAW SRM 53-10-00. REMOVED ANGLE IAW SRM 51-40-21. FABBED NEW ANGLE IAW DWG A53410767. ALODINED IAW SRM 51-21-10. PRIMED AND PAINTED IAW SRM 51-23-10. PART MARKED IAW GMM 7-0-1001. INSTALLED ANGLE IAW SRM 51-40-21. MINOR REPAIR.