What was found
AFT PIT FUSELAGE FRAME HAS CORROSION ON THE WEB AT FRAME 64 BETWEEN STR 49L AND 50L. REMOVED CORROSION IAW SRM 51-74-10. ORIGINAL MATERIAL 0.045; MATERIAL REMOVED 0.017, MATERIAL REMAINING 0.028. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-00. FORMED ANGLE, HEAT TREATED ANGLE IAW TPS 1003; REV A. DRILLED UP PARTS, ALODINED, PRIMED & TOP COATED PARTS IAW SRM 51-40-44, 51-21-10, & 51-23-10. INSTALLED PARTS IAW SRM 53-10-13. ALSO APPLIED TOP COAT ON PARTS IAW SRM 51-23-10.