What was found
FWD CARGO PIT FLOOR PANEL 132GF HAS EDGE DAMAGE AND IS DELAMINATED. FABRICATED NEW FLOOR PANEL. LOCATED HOLES, POTTED EDGES, CURED EDGE POTTING. INSTALLED INSERTS & APPLIED NON-SKID IAW DWG SRZ 25-005; REV F.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO PIT FLOOR PANEL 132GF HAS EDGE DAMAGE AND IS DELAMINATED. FABRICATED NEW FLOOR PANEL. LOCATED HOLES, POTTED EDGES, CURED EDGE POTTING. INSTALLED INSERTS & APPLIED NON-SKID IAW DWG SRZ 25-005; REV F.