What was found
NR 1 PYLON PANEL NR 414 GR IS CORRODED AROUND THE SCREW HOLES. REMOVED THE CORROSION IAW SRM 51-74-10. ORIGINAL MAT THICKNESS .079 IAW SRM 54-52-51; PG 12. REMOVED .059; .020 MAT REMAINING. OUT OF LIMITS IAW SRM 54-52-51; FIG 101. FABBED FILLER/DOUBLER AND REMOVED DAMAGE IAW SRM 54-52-51; FIG 203. ALODINED FILLER/DOUBLER IAW SRM 51-21-10. PRIMED FILLER/DOUBLER IAW SRM 51-23-10. PAINTED FILLER/DOUBLER IAW SRM 51-23-10. INSTALLED FILLER/DOUBLER IAW SRM 54-52-51;FIG 203.