What was found
AFT CARGO FLOOR SUPPORT AT BETWEEN STA 1320-1340, RBL 12, HAS CORROSION AROUND NUT PLATE HOLES. REMOVED CORROSION IAW SRM 51-10-02, L= 2", W= 1", D= .013", ORIGINAL MATERIAL THICKNESS .063". FOUND TO BE OUT OF SRM 53-00-53, FIG 101, SHEET 2 LIMITS. FABRICATED NEW FLOOR SUPPORT ON TRAVELER NR T7/718075 FROM BAC1517-2226. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 53-00-53 AND 51-40-02. THIS IS A MINOR REPAIR WITH NO FOLLOW UP ACTION REQUIRED.