As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PIT HAS CORROSION ON THE BOTTOM OF THE FLOORBEAM AT FRAME 37; LBL 103CM (40.5). REMOVED CORROSION FROM THE BOTTOM OF FLOORBEAM 37; Y 1000 TO 1030 IAW SRM 51-74-10; PG 210. ORIGINAL THICKNESS .126 IAW SRM 53-14-15; PG 9 AND DRAWING A53779635. MATERIAL REMOVED .054. OUT OF LIMITS IAW SRM 53-10-15. INSTALLED REQUIRED REPAIR IAW SRM 53-10-15; FIG 206.