As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LOWER FUSELAGE FWD CARGO DOOR CUTOUT AT FRAME 25; STA 1711 LOWER VERTICAL SECTION HAS A GOUGE ON THE EDGE. REMOVED GOUGES IAW A310-200 SRM 51-74-10. ORIGINAL THICKNESS 0.236; REMAINING MATERIAL 0.230; MATERIAL REMOVED 0.006. FOUND TO BE WITHIN LIMITS IAW A310-200 SRM 53-13-12. ALODINED IAW SRM 51-21-10. PRIMED AND PAINTED IAW SRM 51-23-10.