What was found
MCD FLOOR SUPPORT HAS CORROSION, STA 1660-1681, RBL1, WL 208. REMOVED CORROSION, L= 2", W= .75", D= .010", ORIGINAL MATERIAL THICKNESS .050" FOUND TO BE OUT OF SRM 53-00-51, FIG 101, DETAIL III LIMITS. REMOVED FLOOR SUPPORT CHANNEL IAW SRM 51-40-02. FABRICATED REPLACEMENT CHANNEL ON MAE TRAVELER NR T8/732409, FROM 7075-0 .050B, HEAT TREATED TO T6. INSTALLED REPLACEMENT CHANNEL IAW SRM 51-40-02. THIS IS A CATEGORY "A", MINOR REPAIR WITH NO RECURRING INSPECTIONS.