What was found
EXTERNAL FUSELAGE, FRAME 38, 9 INCHES ABOVE STRINGER 43 RIGHT, SMALL DENT ON RIVET. FOUND DENT TO BE OUT OF LIMITS IAW SRM 53-10-12, REMOVED DAMAGE IAW SRM 53-10-12. FABBED REPAIR PARTS IAW SRM 53-10-12. ALODINED IAW SRM 51-21-10. PRIMED AND PAINTED IAW SRM 51-23-10. INSTALLED REPAIR IAW SRM 53-10-12 & 51-40-21. NDT ACCOMPLISHED PER NTM 51-10-08. NO FUTHER DAMAGE NOTED.