What was found
AFT FUSELAGE, RIGHT EXTERNAL SKIN AT STA 2144 TO STA 2164, FOUND EXFOLIATION CORROSION AT LOWER EDGE OF FIXED FAIRING (347DF) MOUNTING AREA. CORROSION REMOVED PER SRM 51-31-01 VOLUME II. ORIGINAL THICKNESS = 0.095", MATERIAL REMOVED = 0.058", REMAINING THICKNESS = 0.037" AND FOUND EXCEEDED LIMIT PER SRM 53-20-00 FIGURE 13 VOLUME I. REPAIR CARRIED OUT PER SRM 53-20-00 FIGURE 13 VOLUME I. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.