What was found
MAIN DECK, RIGHT FUSELAGE FRAME AT STATION 1681, LONGERON 12 RIGHT FOUND DENTED. REPAIRED AS PER SRM 53-30-00 FIGURE 1 VOLUME I. REPETITIVE INSPECTION REQUIRED - INITIAL INSPECTION AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT AS PER SRM 53-30-00 FIGURE 1 VOLUME I. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.