What was found
MAIN DECK, LEFT FUSELAGE FRAME AT STATION 1721, LONGERON 12 LEFT FOUND DENTED. REPAIRED AS PER SRM 53-30-00 FIGURE 1 VOLUME I. REPETITIVE INSPECTION REQUIRED - INITIAL INSPECTION AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT AS PER SRM 53-30-00 FIGURE 1 VOLUME I. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.