What was found
MAIN DECK CARGO DOOR LOWER JAMB SPOOL FITTING NR 7 FOUND SECOND LAYER CRACK INDICATION AFTER BORE TO MAXIMUM 0.519 INCH. REPAIR CARRIED OUT PER EA 1-5310-120552, REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK CARGO DOOR LOWER JAMB SPOOL FITTING NR 7 FOUND SECOND LAYER CRACK INDICATION AFTER BORE TO MAXIMUM 0.519 INCH. REPAIR CARRIED OUT PER EA 1-5310-120552, REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.