As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
UPPER CARGO DOOR CUT OUT, NR 6 LOWER JAMB SUPPORT FITTING MOUNTING HOLE CRACKED. MOUNTING HOLES REAMED PER SRM 53-50-00 FIG. 10 VOL.I. AND BUSHING REPAIR CARRIED OUT PER SRM 53-50-00 FIG. 10. VOL.I. BUSHING FABRICATED PER SRM 53-50-00 FIG. 10 VOL.I. REPAIR CLASSIFIED AS MINOR AS PER FEDEX GMM 6-2-100.