What was found
FWD PIT SHEAR TIE STA 520 BETWEEN STR 28L-28R CORRODED. REMOVED FASTENER'S TO ACCESS CORROSION IN REF TO SRM 51-30-2 PG 2. REMOVED CORROSION ON FWD SIDE OF SHEAR TIE BS 520 STR 28L-28R IN REF TO SRM 53-10-1. CHECK SHEAR TIE FOR MAT'L LOSS ORIGINAL THICKNESS .042 INCH. REMOVED .003 INCH, REMAINING MAT'L .039 INCH. PER ITEM 3 MAT'L LOSS IS LESS THAN 109.3 IS WITHIN LIMITS REF SRM 53-10-1 FIG 1. TREATED AND PRIMED SHEAR TIE IN REF TO SRM 51-10-2 PG 7. PAINTED SHEAR TIE IN REF TO M/M 51-20-151-07. REINSTALLED FASTENERS IN REF TO SRM 51-30-2 PG 2. THIS IS CLASSIFIED AS A MINOR REPAIR.