What was found
LWR FUSELAGE AFT PIT CORROSION ON INTERCOSTAL AT STA 885 FROM 28L TO 29L. REMOVED CORROSION AND EVALUATED AREA ORIGINAL MAT 0.032, MAT. REMAINING 0.029, MAT LOSS 0.003". TREATED AND PRIMED IAW SRM 51-10-06, 51-10-01 FIG 1, 51-10-02 AND SOPM 20-30-03.