What was found
MAIN DECK FLOOR TRACK AT RBL 38, FRAME 52 HAS CORROSION IN THE CENTER OF THE TRACK. ORIGINAL ADAPTER WAS FOUND TO BE OUT OF LIMITS REF 53-16-10; SRM. INSTALLED NEW ADAPTER REF SRM 51-40-21; PARA 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR TRACK AT RBL 38, FRAME 52 HAS CORROSION IN THE CENTER OF THE TRACK. ORIGINAL ADAPTER WAS FOUND TO BE OUT OF LIMITS REF 53-16-10; SRM. INSTALLED NEW ADAPTER REF SRM 51-40-21; PARA 7.