What was found
CABIN : AFT CABIN AT APPROXIMATELY STATION 1741 LT LONGERON 12 FOUND FRAME DENTED. REPAIRED PER SRM 53-30-00 FIG.1, VOL.I. REPETITIVE INSPECTION REQUIRED, INITIAL INSPECTION AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT AS PER SRM 53-30-00, FIG.1, VOL.I. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.