What was found
AFT CABIN AT APPROXIMATELY STATION 1681 LEFT SIDE LONGERON 12 FOUND FRAME DENTED. REPAIRED AS PER SRM 53-30-00 FIG.1,VOL.I. REPETITIVE INSPECTION REQUIRED, INITIAL INSPECTION AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT AS PER SRM 53-30-00,FIG.1, VOL.I. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.