What was found
AFT MAIN DECK FLOOR DITCHING PANS PAN ASSY IS CRACKED BS 1176 - 1183, LBL 37-47, WL 208. REMOVED DITCHING PAN, FABRICATED, HEAT TREATED TO T-6 CONDITION, ALODINED AND PRIMED AND INSTALLED NEW PAN, REF SRM 51-30-2 PG 1, CWG 65-29549, MM 51-30-05 PG1, SRM 51-10-2 PG 7, MM 51-20-151-07 PG 1, SRM 51-20-04 PG1-4. THIS IS CLASSIFIED AS A MINOR REPAIR.