What was found
AFT MAIN DECK FLOOR DITCHING PAN ASSY IS CRACKED WITH INTERIM COMPOSITE REPAIR BS 1176 - 1183, RBL 18-27, WL 208 REMOVED OLD DITCHING PAN. FABRICATED NEW DITCHING PAN OUT OF 6061-O, HEAT TREATED TO T-6, DRILLED TRIMMED, TREATED PRIMED AND INSTALLED. REF BAC DWG 65- 29548, FED EX GMM 7-0-1001, THIS IS CLASSIFIED AS A MINOR REPAIR.