What was found
C-2 PIT Z - ANGLE FROM STA 960 TO 1036, RT SIDE, HAS SEVERAL LOOSE/MISSING NUT PLATES WITH AREAS OF LIGHT CORROSION ON PANEL REMOVED CORROSION, ORIGINAL THICKNESS, .062 INCH, REMOVED .037 INCH, REMAINING THICKNESS .025 INCH. OUT OF LIMITS. VERIFIED NEW PART 65-57568U26. TRANSFERRED HOLES TO NEW PART. TREATED AND PRIMED. ATTACHED SUPPORT TO NEW Z ANGLE REF SRM 53-10-1 PG 2 - 2A, SRM 51-30-5 PG 1, SRM 51-10-2 PG 7 AND 8, AND BOEING DWG 65-57567.