What was found
MAIN DECK CARGO DOOR SPOOL FITTING NR 5 FOUND 3RD LAYER CRACK INDICATION AT FITTING MOUNTING BOLT HOLE D. MAIN DECK CARGO DOOR SPOOL FITTING NR 5 REMOVED AS PER SRM 51-31-01 VOLUME II AND REPLACED AS PER SRM 51-33-01 VOLUME II. BUSHING REPAIR CARRIED OUT AS PER SRM 53-50-00 FIGURE 10 VOLUME I. REPAIR CLASSIFIED MAJOR PER GMM 6-2-100.