What was found
PREVIOUS EXTERNAL REPAIR DOUBLER LOCATED ON RIGHT WING O/B FLAP UPPER MAIN SKIN UNDER RUB STRIP BETWEEN RIB 3 AND FLAP TRACK NR 3 AND 5.7 INCH FWD OF REAR SPAR MEASURING 11.3 INCH BY 3.9 INCH. REPAIR NOT IAW SRM REQUIREMENTS. REMOVED PREVIOUS REPAIR AND INSTALLED AN APPROVED REPAIR ON RIGHT WING O/B FLAP UPPER MAIN SKIN UNDER RUB STRIP BETWEEN RIB 3 AND FLAP TRACK NR 3 AND 5.7 INCH FWD OF REAR SPAR IAW FEDEX EA6-5750-121299. THIS IS AN APPROVED REPAIR AND IS A RESULT OF AGING AIRCRAFT INSPECTION.