What was found
STATION 344 STR 11R STRINGER TIE MIS-DRILLED AND HAS A FASTENER WITH ZERO EDGE DISTANCE. INSTALLED FRAME REPAIR, FILLER AND STRINGER CLIP IAW SRM 51-30-2, 53-10-4 FIG 1, 53-10-2 FIG 3 AND 51-20-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STATION 344 STR 11R STRINGER TIE MIS-DRILLED AND HAS A FASTENER WITH ZERO EDGE DISTANCE. INSTALLED FRAME REPAIR, FILLER AND STRINGER CLIP IAW SRM 51-30-2, 53-10-4 FIG 1, 53-10-2 FIG 3 AND 51-20-1.