What was found
ORIGINAL DISCREPANCY STILL EXISTS. AFT PIT LT SIDE WALL BODY FRAME IB FLANGE CHAFED, 1148, STR 21L - L CHECKED WEAR AREA FOR MATERIAL LOSS, ORIGINAL THICKNESS "T' .065' MATERIAL LOSS MEASURE .017', REMAINING MATERIAL .048' AND IS OUT OF LIMITS REF SRM 53-10-1 FIG 1. FABRICATED REPAIR MATERIAL REF SRM 51-40-3, INSTALL REPAIR, REF SRM 51-40-3. THIS IS CLASSIFIED AS A MAJOR REPAIR.