What was found
MAIN CABIN FLOORBEAM STA 1640 RBL 47-51 HAS CORROSION BLENDED AREA IAW SRM 51-10-02, ORIG MAT. .125 AFTER 0.90 FOUND OUT LIMITS, IAW SRM 53-00-51 PAGE 103, CUT OUT DAMAGED AREA STA 1640 BET RBL36.5 TO RBL 68.5, IAW SRM 53-00-51 PAGE 201. RECEIVED REPAIR PARTS NR 1 TEE CHORD, NR 2 ANGLE FAB`D. ON TRAV NR T8/746064 PART NR 3 REPAIR ANGLE FAB`D. ON TRAV NR T8/746065, AND STRAP NR 4 AND 5 FAB`D IAW SRM 53-00-51 PAGE 203 FIG 201. LOCATED AND DRILLED FASTENERS HOLES REPAIR PARTS DEBURRED, TRIMED AND TREATED AND PRIMED IAW SRM 51-20-01 AND SRM 51-40-05. INSTALLED REPAIR PARTS IAW SRM 53-00-51 IAW SRM 51-40-02. CATEGORY A REPAIR NO FOLLOW UP TRACKING REQUIRED.