What was found
DURING OPEN HOLE HFEC INSPECTION, MAIN CARGO DOOR LOWER JAMB SUPPORT FITTING NR 3 FOUND WITH CRACK INDICATIONS AT HOLES NR A AND NR B (3RD LAYER). MOUNTING HOLES NR A AND NR B ON THE MAIN CARGO DOOR NR 3 JAMB SUPPORT BUSHING REPAIR CARRIED OUT AS PER SRM 53-50-00 FIG 10 VOL I. CRACK FITTING ON NR 3 JAMB AREA REMOVED AND REPLACED WITH A NEW FITTING AS PER SRM 51-33-01 VOL II. REPAIR CLASSIFIED AS MAJOR AS PER FEDEX GMM 6-2-100.