What was found
MAIN DECK CARGO COMPARTMENT, CORROSION FOUND ON PRESSURE BOUNDARY OVERWING UPPER SURFACE AT STA Y= 1227 TO 1228, XCW= 96-97 RT UPPER SURFACE CORROSION ON MAIN DECK CARGO COMPARTMENT AT STA Y=1227 TO STA 1228 XCW 96- 97. REMOVED AS PER SRM 51-21-01 VOL II AND FOUND WITHIN LIMIT AS PER SRM 57-20-00 FIG 13 VOL I. ORIGINAL THICKNESS:0.175 INCH, MATERIAL REMOVED:0.026 INCH, REMAINING THICKNESS:0.149 INCH. REPAIR CLASSIFIED AS MINOR AS PER FEDEX GMM 6-2-100.