What was found
MAIN DECK CARGO COMPARTMENT, CORROSION FOUND ON UPPER SURFACE OF PRESSURE BOUNDARY OVERWING AT STA Y=1228, XCW= 63.5-64.5 RT. UPPER SURFACE CORROSION ON MAIN DECK CARGO COMPARTMENT AT STA Y=1228 XCW=63.5-64.5. REMOVED AS PER SRM 51-21-01 VOL II AND FOUND WITHIN LIMIT AS PER SRM 57-20-00 FIG 13 VOL I. ORIGINAL THICKNESS: 0.169 INCH, MATERIAL REMOVED: 0.014 INCH, REMAINING THICKNESS: 0.155 INCH. REPAIR CLASSIFIED AS MINOR AS PER FEDEX GMM 6-2-100.