What was found
FUSELAGE CREASE BEAM WEB CRACKED, STR17L, BS-640-660 FABRICATED NEW CREASE BEAM WEB PER SAMPLE AND BOEING DWG NR 65-58536. TRANSFERED NEW FASTENER HOLES REF, SRM 51-30-2, PG 1-10. TREATED AND PRIMED WEB, REF: SRM 51-10-2, PG 1-2. WEB BE INSTALLED ON NR N00796, JPF LINE ITEM 2. THIS IS CLASSIFIED AS A MINOR REPAIR.