What was found
MAIN DECK CROSSBEAM C14(FR14) -Y1220 TO -Y1300 LOWER FREE FLANGE WITH EXFOLIATION CORROSION. REMOVED THE PULLEY BRACKET PER AMM 20-29-11-0. REMOVED CORROSION PER SRM 51-74-10. APPLIED ALODINE TO THE REWORKED AREA PER SRM 51-21-10. MEASURED REMAINING THICKNESS IS 0.096 INCH PER NTM51-10-04. IT IS WITHIN THE LIMIT PER SRM 53-12-15-101. APPLIED FLAP PEENING INTENSITY=0.15MM.N TO THE REWORKED AREA PER SRM 51-29-00. APPLIED PAINT PER SRM 51-75-10. INSTALLED PULLEY BRACKET PER AMM 20-29-11-0. PERFORMED INSPECTION TO THE REWORKED AREA PER SRM 53-12-15-1-001-00.