What was found
LT PAX/CREW DOOR LONGERON POSITION NR 2 WITH MILD/EXFOLIATION CORROSION BETWEEN FR15A-16. REMOVED CORROSION PER SRM 51-74-10. APPLIED ALODINE TO THE REWORKED AREA PER SRM 51-21-10. MEASURED REMAINING THICKNESS PER NTM 51-10-04. THE ORIGINAL THICKNESS IS 0.063 INCH PER DWG:A52111307 ALLOWABLE DAMAGE IS 20 PERCENT PER SRM 52-10-00. EXCEEDED LIMIT. CUT OUT THE CORRODED AREA AND DEBURR THE CUT EDGES PER SRM 52-10-00. FABRICATED THE REPAIR PART PER SRM 52-10-00. DRILLED FASTENER HOLES TO THE REPAIR PART PER SRM 51-40-50. APPLIED ALODINE TO THE REPAIR PART PER SRM 51-21-10. APPLIED PRIMER TO THE REPAIR PART PER SRM 51-75-10. INSTALLED THE REPAIR PART PER SRM 51-40-21. APPLIED FINISH PER SRM 51-75-10.