What was found
MAIN DECK CARGO DOOR LOWER JAMB SUPPORT FITTING NR 6 FOUND 3RD LAYER CRACK INDICATION AT HOLE A, B, C AND D. MAIN DECK CARGO DOOR LOWER JAMB CRACKED SUPPORT FITTING NR 6 REMOVED AND REPLACED AS PER SRM 51-31-01 VOLUME II. REPAIR BUSHINGS FABRICATED AND INSTALLED AS PER SRM 53-50-00 FIGURE 10 VOLUME I. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.