What was found
FUSELAGE OUTER CREASE BEAM CHORD (STR 17L) CRACKED REMOVED CREASE BEAM CHORD, STR 17L, FROM STE 620 TO STA 663. VERIFIED MATERIAL TO BE BAC1506-1133 7075-T-6, ATAG NR A00531. LOCATED AND DRILLED FASTENER HOLES IN NEW CHORD. TREATED AND PRIMED NEW CHORD. INSTALLED NEW CHORD AND APPLIED CORROSION INHIBITOR COMPOUND REF SRM 51-30-02 PG 2, SRM 53-10-2 FIG 9, SRM 51-30-30 5 PG 3-5, SRM 51-40-4 FIG 1, SRM 51-20-014 -7, PG 1-7. THIS IS CLASSIFIED AS A MAJOR REPAIR.